Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 337-344, 2023.
Article in Chinese | WPRIM | ID: wpr-961339

ABSTRACT

Objective @#To evaluate the effect of anatomical healing abutments for mandibular first molars on the morphological changes of gingival soft tissue after implant restoration, as well as on peri-implant gingival molding, food ingrowth and patient satisfaction, to provide a basis for clinical selection. @*Methods @# Twenty-six patients who received implant restoration for a single missing mandibular first molar between September 2020 and September 2021 at the Oral Implant Center of Changsha Stomatological Hospital were randomly divided into a control group (13 cases with 14 implants) and a trial group (13 cases with 14 implants), of which 12 were male and 14 were female; the trial group had anatomical healing abutments applied for 4 weeks and then underwent crown restoration, while the control group finished five time points (before the second stage surgery, 4 weeks after the second stage surgery, immediately after the crown restoration, 4 weeks after the crown restoration, and 12 weeks after the crown restoration). A 3Shape intraoral scanner was used to scan the jaw before and 4 weeks after the second stage surgery to quantify the soft tissue changes and compare the effect of the healing abutment on gingival molding between the two groups. The incidence of food impaction was recorded and compared between the two groups at 4 weeks and 12 weeks after crown restoration. Patient satisfaction was recorded and compared between the two groups immediately after crown restoration, 4 weeks after crown restoration and 12 weeks after crown restoration@*Results @# Four weeks after implant surgery, it was observed that the gingival proximal and distal gingival papillae increased on the coronal side in the test group compared to the control group, 0.50 (0.26, 0.72) mm in the near-medium test group and 0.27 (0.24, 0.38) mm in the control group, with a statistically significant difference (P = 0.029), and 0.48 (0.26, 0.62) mm in the far-medium test group and 0.23 (0.13, 0.39) mm in the control group, with a statistically significant difference (P = 0.004). There was no statistically significant difference (P>0.05) in the buccolingual to gingival margin apex to coronal molding or in the buccolingual to lingual soft tissue at 0, 1, or 2 mm of the root of the middle 1/3 apex of the buccal and lingual gingival margins between the two groups. Compared to the control group, there was no statistically significant difference in the incidence of food impaction observed 4 weeks and 12 weeks after crown restoration in the test group (P>0.05). The satisfaction scores were higher in the trial group than in the control group immediately, 4 weeks, and 12 weeks after crown restoration, and the difference between the groups was statistically significant (P < 0.05). @*Conclusion @# The anatomical healing abutment for the implant mandibular first molar was superior to the finished healing abutment in terms of soft tissue contouring with an increase in the coronal aspect of the proximal and distal gingival papillae, resulting in high patient satisfaction.

2.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 207-211, 2022.
Article in Chinese | WPRIM | ID: wpr-907046

ABSTRACT

Objective@# To explore the design and manufacture of anatomical healing abutment for mandibular first molar implant in order to provide more choices for clinical healing abutment@*Methods@# The buccal lingual diameter and mesial distal diameter of the tooth neck, as well as the slope data of the four axial surfaces of the natural isolated teeth, were obtained by scanning the isolated mandibular first molar with a shining scanner. After statistical analysis of the data, the anatomical healing abutment of the mandibular first molar was designed and constructed using computer aided design/computer aided manufacturing (CAD/CAM).@*Results@#The mean buccal and lingual diameters of the mesial and distal diameters of the isolated mandibular first molars were (8.54 ± 0.78) mm and (7.87 ± 0.86) mm, and the tooth neck slopes of each axial surface of the isolated mandibular first molars were 17.53 °(buccal), 14.41 °(lingal), 13.40 °(mesial) and 13.43 °(distal), respectively. Three anatomical healing abutments with different peripheral diameters and heights of 5 mm were obtained according to a certain proportion of reduction of the natural teeth of the mandibular first molars@*Conclusion@#The anatomical healing abutment of the mandibular first molar can be quickly obtained by Shining scanning and CAD/CAM technology.

3.
Journal of Periodontal & Implant Science ; : 171-184, 2019.
Article in English | WPRIM | ID: wpr-766102

ABSTRACT

PURPOSE: To evaluate the effects of intra-alveolar socket grafting, subepithelial connective tissue grafts, and individualized abutments on peri-implant hard and soft tissue outcomes following immediate implant placement. METHODS: This randomized experimental study employed 5 mongrel dogs, with 4 sites per dog (total of 20 sites). The mesial roots of P3 and P4 were extracted in each hemimandible and immediate dental implants were placed. Each site was randomly assigned to 1 of 4 different treatment groups: standardized healing abutment (control group), alloplastic bone substitute material (BSS) + standardized healing abutment (SA group), BSS + individualized healing abutment (IA group), and BSS + individualized healing abutment + a subepithelial connective tissue graft (IAG group). Clinical, histological, and profilometric analyses were performed. The intergroup differences were calculated using the Bonferroni test, setting statistical significance at P<0.05. RESULTS: Clinically, the control and SA groups demonstrated a coronal shift in the buccal height of the mucosa (0.88±0.48 mm and 0.37±1.1 mm, respectively). The IA and IAG groups exhibited an apical shift of the mucosa (−0.7±1.15 mm and −1.1±0.96 mm, respectively). Histologically, the SA and control groups demonstrated marginal mucosa heights of 4.1±0.28 mm and 4.0±0.53 mm relative to the implant shoulder, respectively. The IA and IAG groups, in contrast, only showed a height of 2.6 mm. In addition, the height of the mucosa in relation to the most coronal buccal bone crest or bone substitute particles was not significantly different among the groups. Volumetrically, the IA group (−0.73±0.46 mm) lost less volume on the buccal side than the control (−0.93±0.44 mm), SA (−0.97±0.73 mm), and IAG (−0.88±0.45 mm) groups. CONCLUSIONS: The control group demonstrated the most favorable change of height of the margo mucosae and the largest dimensions of the peri-implant soft tissues. However, the addition of a bone substitute material and an individualized healing abutment resulted in slightly better preservation of the peri-implant soft tissue contour.


Subject(s)
Animals , Dogs , Bone Substitutes , Connective Tissue , Dental Implants , Mucous Membrane , Shoulder , Tissue Transplantation , Transplants
4.
The Journal of Korean Academy of Prosthodontics ; : 432-438, 2019.
Article in Korean | WPRIM | ID: wpr-761448

ABSTRACT

Accurate impression taking for the success of implant prosthesis is a very important process. Methods of taking implant impression include the conventional method using impression coping and impression material, and the digital method using an intraoral scanner and scanbody. However, the impression coping or the scanbody must install after remove healing abutment. Because of this, the dentist must repeat the process of removing and installing the healing abutment, the impression coping or the scanbody several times. In addition, the impression coping or the scanbody rises higher than the occlusal surface, so the patient has the inconvenience of constantly maintaining the open state. Recently, a scannable healing abutment, which can be scanned by a intraoral scanner directly, without the need to remove the healing abutment by applying a scannable part of the scanbody to the healing abutment, was introduced. We present a case of single posterior implant prosthesis using a scannable healing abutment.


Subject(s)
Humans , Dentists , Methods , Prostheses and Implants
5.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 379-383, 2018.
Article in Chinese | WPRIM | ID: wpr-777830

ABSTRACT

Implant restoration ; Provisional restoration ; Healing abutment ; Esthetic zone ; Esthetic outcomes@#To compare the esthetic outcomes of peri-implant soft tissue conditioning with provisional restorations and healing abutments.@*Methods @#A total of 48 patients missing a single tooth in the esthetic zone were chosen for the present study and divided into two groups. Twenty-six patients in Group A used provisional restorations to condition the peri-implant soft tissue before final restorations, while 22 patients in Group B used healing abutments to condition the soft tissue. All patients were evaluated by pink esthetic scores (PESs) at the time of the final restoration and at a 1-year follow-up. @*Results@#A total of 26 implants in Group A and 22 implants in Group B showed good peri-implant soft tissue condition. PESs at the time of the final restoration and at the 1-year follow-up in Group A were 8.18 and 8.35, respectively, and 6.73 and 8.18 in Group B, respectively. PESs at the time of final restoration and at the 1-year follow-up were not significantly different in Group A but were significantly different in Group B. The PESs of the two groups were significantly different at the final restoration but were not significantly different at the 1-year follow-up. @*Conclusions @#Provisional restoration in the esthetic zone can improve the pink esthetic effect when permanent restoration.

6.
Journal of Dental Rehabilitation and Applied Science ; : 338-344, 2016.
Article in English | WPRIM | ID: wpr-222969

ABSTRACT

Implant supported removable partial denture (ISRPD) using the implants enables favorable rehabilitation by complementing biomechanical limitations of the conventional removable partial denture (RPD). However, continuous recall check is necessary for evaluation of the mechanical and biological complications to ensure good long-term prognosis of ISRPD. This clinical report describes the complication and management in patient of Kennedy class I edentulism with ISRPD using healing abutment. The wear and fracture of healing abutment occurred at 36 months after delivery. So, healing abutment was replaced by connecting Locator® abutment for altering into the implant retained partial overdenture.


Subject(s)
Humans , Complement System Proteins , Denture, Overlay , Denture, Partial, Removable , Prognosis , Rehabilitation
7.
The Journal of Korean Academy of Prosthodontics ; : 105-110, 2015.
Article in Korean | WPRIM | ID: wpr-87268

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. MATERIALS AND METHODS: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (alpha=.05). RESULTS: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were 0.755#x00B0; in sagittal plane, and 1.275#x00B0; in coronal plane, and 0.420#x00B0; in horizontal plane. CONCLUSION: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.


Subject(s)
Humans , Dental Implants , Molar , Seoul , Tooth
8.
The Journal of Korean Academy of Prosthodontics ; : 222-227, 2015.
Article in Korean | WPRIM | ID: wpr-39287

ABSTRACT

Aesthetic impression is emphasized in the recent field of implant restoration. However, there is limitation of creating proper shape of soft tissue as well as cervical emergence profile due to the use of pre-existing healing abutment in the process of initial post-operative soft tissue healing period. Designing the shape of abutment into the final customized abutment instead of its original shape helped to achieve more aesthetic implant restoration by applying healing abutment which could minimize the malposition and recession of soft tissue. In this study, soft tissue healing was promoted using the post-operative customized healing abutment and thereby obtained the result of more aesthetic and functional restoration by minimizing displacement of soft tissue in the process of applying final customized abutment.

SELECTION OF CITATIONS
SEARCH DETAIL